Ich verwendet jetzt NUT (Network UPS Tools)
Qnap NAS
RBC17
BE700G-GR / BK650EI und andere.
Gerald
RBC2
kompatibel APC Back-UPS RS 500 BR500 RBC2
Gerald Aubing RBC2
Unterbrechungsfreie Stromversorgung (USV: CS 350 von APC) und Debian
Die Ups per USB anschliessen:
/tail var/log/messages:
Apr 25 13:16:46 kuskus kernel: usb 1-1: new low speed USB device using uhci_hcd and address 3
Apr 25 13:16:47 kuskus kernel: usb 1-1: configuration #1 chosen from 1 choice
Apr 25 13:16:48 kuskus kernel: hiddev96: USB HID v1.10 Device [American Power Conversion Back-UPS CS 350 FW:807.q5.I USB FW:q5] on usb-0000:00:1d.0-1
http://www.seismo.ethz.ch/linux/apc_usv.html
apt-get install apcupsd
Beispielkonfiguration in: /etc/default/apcupsd
Eigentliche Konfiguration in /etc/apcupsd/apcupsd.conf
Dort:
UPSCABLE usb (war: smart)
UPSTYPE usb (war: apcsmart)
NIS: (Network information server):
NISIP 192.168.123.95 (war: 127.0.0.1)
NISPORT 3551
Wenn alles konfiguriert: /etc/init.d/apcupsd start
(Wenn man vorher start, (mit smart und so), dann muss der Prozess mit kill deendet werden: ps -A | grep apc; kill x)
Infos:
apcaccess
APC : 001,040,0977 DATE : Tue May 20 16:34:09 CEST 2008 HOSTNAME : kuskus RELEASE : 3.12.4 VERSION : 3.12.4 (19 August 2006) debian UPSNAME : kuskus CABLE : USB Cable MODEL : Back-UPS CS 350 UPSMODE : Stand Alone STARTTIME: Tue May 13 11:56:11 CEST 2008 STATUS : ONLINE LINEV : 226.0 Volts LOADPCT : 44.0 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 24.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds OUTPUTV : 230.0 Volts DWAKE : 000 Seconds DSHUTD : 000 Seconds LOTRANS : 180.0 Volts HITRANS : 266.0 Volts RETPCT : 000.0 Percent ITEMP : 29.2 C Internal ALARMDEL : Always BATTV : 13.5 Volts LINEFREQ : 50.0 Hz LASTXFER : Low line voltage NUMXFERS : 0 TONBATT : 0 seconds CUMONBATT: 0 seconds XOFFBATT : N/A SELFTEST : NO STATFLAG : 0x07000008 Status Flag SERIALNO : BB0448012628 BATTDATE : 2004-11-24 NOMBATTV : 12.0 FIRMWARE : 07.q5.I USB FW:q5 APCMODEL : Back-UPS CS 350 END APC : Tue May 20 16:34:11 CEST 2008
Meine /etc/apcupsd/apcupsd.conf
:
## apcupsd.conf v1.1 ## # # for apcupsd release 3.12.4 (19 August 2006) - debian # # "apcupsd" POSIX config file # # ========= General configuration parameters ============ # # UPSNAME xxx # Use this to give your UPS a name in log files and such. This # is particulary useful if you have multiple UPSes. This does not # set the EEPROM. It should be 8 characters or less. #UPSNAME # UPSCABLE <cable> # Defines the type of cable connecting the UPS to your computer. # # Possible generic choices for <cable> are: # simple, smart, ether, usb # # Or a specific cable model number may be used: # 940-0119A, 940-0127A, 940-0128A, 940-0020B, # 940-0020C, 940-0023A, 940-0024B, 940-0024C, # 940-1524C, 940-0024G, 940-0095A, 940-0095B, # 940-0095C, M-04-02-2000 # #UPSCABLE smart UPSCABLE usb # To get apcupsd to work, in addition to defining the cable # above, you must also define a UPSTYPE, which corresponds to # the type of UPS you have (see the Description for more details). # You must also specify a DEVICE, sometimes referred to as a port. # For USB UPSes, please leave the DEVICE directive blank. For # other UPS types, you must specify an appropriate port or address. # # UPSTYPE DEVICE Description # apcsmart /dev/tty** Newer serial character device, # appropriate for SmartUPS models using # a serial cable (not USB). # # usb <BLANK> Most new UPSes are USB. # A blank DEVICE setting enables # autodetection, which is th best choice # for most installations. # # net hostname:port Network link to a master apcupsd # through apcupsd's Network Information # Server. This is used if you don't have # a UPS directly connected to your computer. # # snmp hostname:port:vendor:community # SNMP Network link to an SNMP-enabled # UPS device. Vendor is the MIB used by # the UPS device: can be "APC", "APC_NOTRAP" # or "RFC" where APC is the powernet MIB, # "APC_NOTRAP" is powernet with SNMP trap # catching disabled, and RFC is the IETF's # rfc1628 UPS-MIB. Port is usually 161. # Community is "private". # # dumb /dev/tty** Old serial character device for use # with simple-signaling UPSes. # #UPSTYPE apcsmart #DEVICE /dev/ttyS0 UPSTYPE usb # LOCKFILE <path to lockfile> # Path for device lock file. LOCKFILE /var/lock # # ======== Configuration parameters used during power failures ========== # # The ONBATTERYDELAY is the time in seconds from when a power failure # is detected until we react to it with an onbattery event. # # This means that, apccontrol will be called with the powerout argument # immediately when a power failure is detected. However, the # onbattery argument is passed to apccontrol only after the # ONBATTERYDELAY time. If you don't want to be annoyed by short # powerfailures, make sure that apccontrol powerout does nothing # i.e. comment out the wall. ONBATTERYDELAY 6 # # Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so # the first that occurs will cause the initation of a shutdown. # # If during a power failure, the remaining battery percentage # (as reported by the UPS) is below or equal to BATTERYLEVEL, # apcupsd will initiate a system shutdown. BATTERYLEVEL 5 # If during a power failure, the remaining runtime in minutes # (as calculated internally by the UPS) is below or equal to MINUTES, # apcupsd, will initiate a system shutdown. MINUTES 3 # If during a power failure, the UPS has run on batteries for TIMEOUT # many seconds or longer, apcupsd will initiate a system shutdown. # A value of 0 disables this timer. # # Note, if you have a Smart UPS, you will most likely want to disable # this timer by setting it to zero. That way, you UPS will continue # on batteries until either the % charge remaing drops to or below BATTERYLEVEL, # or the remaining battery runtime drops to or below MINUTES. Of course, # if you are testing, setting this to 60 causes a quick system shutdown # if you pull the power plug. # If you have an older dumb UPS, you will want to set this to less than # the time you know you can run on batteries. TIMEOUT 0 # Time in seconds between annoying users to signoff prior to # system shutdown. 0 disables. ANNOY 300 # Initial delay after power failure before warning users to get # off the system. ANNOYDELAY 60 # The condition which determines when users are prevented from # logging in during a power failure. # NOLOGON <string> [ disable | timeout | percent | minutes | always ] NOLOGON disable # If KILLDELAY is non-zero, apcupsd will continue running after a # shutdown has been requested, and after the specified time in # seconds attempt to kill the power. This is for use on systems # where apcupsd cannot regain control after a shutdown. # KILLDELAY <seconds> 0 disables KILLDELAY 0 # # ==== Configuration statements for Network Information Server ==== # # NETSERVER [ on | off ] on enables, off disables the network # information server. If netstatus is on, a network information # server process will be started for serving the STATUS and # EVENT data over the network (used by CGI programs). NETSERVER on # NISIP <dotted notation ip address> # IP address on which NIS server will listen for incoming connections. # Default value is 0.0.0.0 that means any incoming request will be # serviced but if you want it to listen to a single subnet you can # set it up to that subnet address, for example 192.168.10.0 # Additionally you can listen for a single IP like 192.168.10.1 #NISIP 127.0.0.1 NISIP 192.168.123.95 # NISPORT <port> default is 3551 as registered with the IANA # port to use for sending STATUS and EVENTS data over the network. # It is not used unless NETSERVER is on. If you change this port, # you will need to change the corresponding value in the cgi directory # and rebuild the cgi programs. NISPORT 3551 # If you want the last few EVENTS to be available over the network # by the network information server, you must define an EVENTSFILE. EVENTSFILE /var/log/apcupsd.events # EVENTSFILEMAX <kilobytes> # By default, the size of the EVENTSFILE will be not be allowed to exceed # 10 kilobytes. When the file grows beyond this limit, older EVENTS will # be removed from the beginning of the file (first in first out). The # parameter EVENTSFILEMAX can be set to a different kilobyte value, or set # to zero to allow the EVENTSFILE to grow without limit. EVENTSFILEMAX 10 # # ========== Configuration statements used if sharing ============= # a UPS and controlling it via the network # The configuration statements below are used if you want to share one # UPS to power multiple machines and have them communicate by the network. # Most of these items are for Master/Slave mode only, however NETTIME is # also used for Client/Server NIS networking with the net driver. # NETTIME <int> # Interval (in seconds) at which the slave or client polls the master # or server. This is applicable to BOTH master/slave and client/server # (NIS) networking. #NETTIME 100 # # Remaining items are for Master/Slave networking ONLY # # UPSCLASS [ standalone | shareslave | sharemaster | netslave | netmaster ] # Normally standalone unless you share a UPS with multiple machines. # UPSCLASS standalone # UPSMODE [ disable | share | net | sharenet ] # Unless you want to share the UPS (power multiple machines), # this should be disable. UPSMODE disable # NETPORT <int> # Port on which master/slave networking communicates. #NETPORT 6544 # MASTER <machine-name> # IP address of the master. Only applicable on slaves. #MASTER # SLAVE <machine-name> # IP address(es) of the slave(s). Only applicable on master. #SLAVE slave1 #SLAVE slave2 # USERMAGIC <string> # Magic string use by slaves to identify themselves. Only applicable # on slaves. #USERMAGIC # # ===== Configuration statements to control apcupsd system logging ======== # # Time interval in seconds between writing the STATUS file; 0 disables STATTIME 0 # Location of STATUS file (written to only if STATTIME is non-zero) STATFILE /var/log/apcupsd.status # LOGSTATS [ on | off ] on enables, off disables # Note! This generates a lot of output, so if # you turn this on, be sure that the # file defined in syslog.conf for LOG_NOTICE is a named pipe. # You probably do not want this on. LOGSTATS off # Time interval in seconds between writing the DATA records to # the log file. 0 disables. DATATIME 0 # FACILITY defines the logging facility (class) for logging to syslog. # If not specified, it defaults to "daemon". This is useful # if you want to separate the data logged by apcupsd from other # programs. #FACILITY DAEMON # # ========== Configuration statements used in updating the UPS EPROM ========= # # # These statements are used only by apctest when choosing "Set EEPROM with conf # file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD. # # UPS name, max 8 characters #UPSNAME UPS_IDEN # Battery date - 8 characters #BATTDATE mm/dd/yy # Sensitivity to line voltage quality (H cause faster transfer to batteries) # SENSITIVITY H M L (default = H) #SENSITIVITY H # UPS delay after power return (seconds) # WAKEUP 000 060 180 300 (default = 0) #WAKEUP 60 # UPS Grace period after request to power off (seconds) # SLEEP 020 180 300 600 (default = 20) #SLEEP 180 # Low line voltage causing transfer to batteries # The permitted values depend on your model as defined by last letter # of FIRMWARE or APCMODEL. Some representative values are: # D 106 103 100 097 # M 177 172 168 182 # A 092 090 088 086 # I 208 204 200 196 (default = 0 => not valid) #LOTRANSFER 208 # High line voltage causing transfer to batteries # The permitted values depend on your model as defined by last letter # of FIRMWARE or APCMODEL. Some representative values are: # D 127 130 133 136 # M 229 234 239 224 # A 108 110 112 114 # I 253 257 261 265 (default = 0 => not valid) #HITRANSFER 253 # Battery change needed to restore power # RETURNCHARGE 00 15 50 90 (default = 15) #RETURNCHARGE 15 # Alarm delay # 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never # BEEPSTATE 0 T L N (default = 0) #BEEPSTATE T # Low battery warning delay in minutes # LOWBATT 02 05 07 10 (default = 02) #LOWBATT 2 # UPS Output voltage when running on batteries # The permitted values depend on your model as defined by last letter # of FIRMWARE or APCMODEL. Some representative values are: # D 115 # M 208 # A 100 # I 230 240 220 225 (default = 0 => not valid) #OUTPUTVOLTS 230 # Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on # SELFTEST 336 168 ON OFF (default = 336) #SELFTEST 336