====== SMART ======
Self-Monitoring, Analysis and Reporting Technology
{{tag>SMART S.M.A.R.T. SMART-Linux smartctl}}
apt-get install smartmontools
Daemon starten:
/etc/default/smartmontools
editieren
Nach Ausführen eines Selbsttests "smartctl -t offline /dev/hda" (wie lange das dauert wird dir angezeigt) :
smartctl -l error /dev/hda
Beispielausgabe:
Titel: SMART Ausgabe
Erstellt von:
Erstellt am 11 January 2008, 10:29
seitdem 68 Mal aufgerufen
als Datei runterladen
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HM100JC
Serial Number: S0CFJ20YC02429
Firmware Version: YN100-12
User Capacity: 100.030.242.816 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
Local Time is: Fri Jan 11 07:55:15 2008 CET
==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details.
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (4421) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 73) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 2944
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1712
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 2
7 Seek_Error_Rate 0x000e 253 253 000 Old_age Always - 0
8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 267580
10 Spin_Retry_Count 0x0032 253 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 959
191 G-Sense_Error_Rate 0x0012 100 100 000 Old_age Always - 6797
192 Power-Off_Retract_Count 0x0012 253 253 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 100 073 000 Old_age Always - 46
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 6843633
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 2
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x0012 253 253 000 Old_age Always - 0
223 Load_Retry_Count 0x0012 100 100 000 Old_age Always - 6
225 Load_Cycle_Count 0x0012 068 068 000 Old_age Always - 325156
255 Unknown_Attribute 0x000a 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 583 -
SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
SMART Selective self-test log data structure revision number 0
Warning: ATA Specification requires selective self-test log data structure revision number = 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
als Datei runterladen